|
Build Your Online Product Catalogs?
Product Name: |
Small dameter bars eddy current testing system made in china
|
Supply Ability: |
300sets |
Related proudcts |
testing equipment, testing system, |
Specifications |
IDEA-ET0X |
Price Term: |
FOB |
Port of loading: |
xiamen |
Minimum Order |
1set |
Unit Price: |
10000-700000 |
|
Small dameter bars eddy current testing system/Testing equipment 1.Independent R&D 2.Factory production,quality assurance 1 Introduction This off-line eddy current ***ecting equipment is used in high accuracy flaw testing for workpiece that already be finished. Automatic testing procedure: Using up-loading system, via roller way, the workpiece was sent to the eddy current ***ecting area, through magnetic saturation, probe, and demagnetization device, finally the off-loading system. Meantime it can automatically alarm, mark, sort according to the testing result. 2 Tested object: Small diameter tube, Small diameter bar, profiled bar(diameter2-6mm) 3 Tested material: Carbon steel, stainless steel, copper, aluminium, titanium etc. Different kinds of nonferrous and ferrous metals. 4 Testing speed: 0-100m/min 5 Testing mode: Off-line flaw ***ecting 6 Testing range: Diameter 2-6mm 7 Testing Standard: GB/T 7735-2004 GB/T 11260-2008 YB/T 4083-2000 GB/T 11260-2008 YB/T 4083-2000 2.Parameters: 1. Testing channel: 1 2 4 8 16 32 2. Frequency range: 10 Hz~10 MHz, to meet various metal material testing requirements. 3. Gain: 0 dB ~ 110dB, continuously adjustable, the work of each file 0.1dB step 4. Phase: 0 ~ 359 ° , continuously adjustable, continuously adjustable, precision 1 ° 5. Gain ratio: (X/Y)0.1~10.0 6. Testing speed: <=120m/min 7. Adjustable probe drive rank: 1~16 8. Fast digital / analog electronic balance 9. Non-amplitude, unsymmetrical phase alarm region setting 10. Various display: Impedance, time base display 11. Digital Filtering: High-pass frequency (0Hz ~ 2000Hz), low-pass frequency (0Hz ~ 2000Hz) 12. Delayed hardware output alarm, real-time hardware output alarm 13. Delayed\fixed length mark, precision0_65536ms/0_9999.999MM 14. Auto balance time: -1~1024 15. Multi-mode inside and outer clock, encoder I/O input and output unit. 16. Resection function for end socket and tail end signal 17. Mass storage of various test procedures and test data 21. E |
Company: |
Xiamen IDEA Electronic Technology Co., Ltd
|
Contact: |
Ms. Liu Emily |
Address: |
Floor 2, NO.20,Tong'an industrial park, Huangdong Waters, Tong'an, |
Postcode: |
|
Tel: |
008613599504218 |
Fax: |
0592-6301919 |
E-mail: |
|
|
|
|